People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Witek, Lukasz
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (42/42 displayed)
- 20233D Printing Type 1 Bovine Collagen Scaffolds for Tissue Engineering Applications—Physicochemical Characterization and In Vitro Evaluationcitations
- 2023Engineering 3D Printed Bioceramic Scaffolds to Reconstruct Critical-Sized Calvaria Defects in a Skeletally Immature Pig Modelcitations
- 2023Three-Dimensional Printing Bioceramic Scaffolds Using Direct-Ink-Writing for Craniomaxillofacial Bone Regeneration. citations
- 2022Residual stress estimated by nanoindentation in pontics and abutments of veneered zirconia fixed dental prosthesescitations
- 2022Physiochemical and bactericidal activity evaluationcitations
- 2022Temporary materials used in prosthodonticscitations
- 2022Stability of fatigued and aged ZTA compared to 3Y-TZP and Al2O3 ceramic systemscitations
- 2021Three-Dimensionally-Printed Bioactive Ceramic Scaffoldscitations
- 2021Nanoscale physico-mechanical properties of an aging resistant ZTA compositecitations
- 2021Effect of supplemental acid-etching on the early stages of osseointegrationcitations
- 2021Hydrothermal aging affects the three-dimensional fit and fatigue lifetime of zirconia abutmentscitations
- 2020Comparative analysis of elastomeric die materials for semidirect composite restorations.
- 2020Bone Tissue Engineering in the Growing Calvaria Using Dipyridamole-Coated, Three-Dimensionally-Printed Bioceramic Scaffoldscitations
- 2020Comparative analysis of elastomeric die materials for semidirect composite restorations
- 2020Microstructural, mechanical, and optical characterization of an experimental aging-resistant zirconia-toughened alumina (ZTA) compositecitations
- 2020Assessing osseointegration of metallic implants with boronized surface treatmentcitations
- 2020Aging resistant ZTA composite for dental applicationscitations
- 2019Long-term outcomes of 3D-printed bioactive ceramic scaffolds for regeneration of the pediatric skeleton
- 2019Osteointegrative and microgeometric comparison between micro-blasted and alumina blasting/acid etching on grade II and V titanium alloys (Ti-6Al-4V)citations
- 2019Physical and chemical characterization of synthetic bone mineral ink for robocasting applications
- 2019Dipyridamole Augments Three-Dimensionally Printed Bioactive Ceramic Scaffolds to Regenerate Craniofacial Bonecitations
- 2019Tissue-engineered alloplastic scaffolds for reconstruction of alveolar defectscitations
- 2019Comparative in vitro study of 3D robocasting scaffolds using beta tricalcium phosphate and synthetic bone mineral
- 2019Synergistic effects of implant macrogeometry and surface physicochemical modifications on osseointegrationcitations
- 2019Repair of Critical-Sized Long Bone Defects Using Dipyridamole-Augmented 3D-Printed Bioactive Ceramic Scaffoldscitations
- 2019Nanomechanical and microstructural characterization of a zirconia-toughened alumina composite after agingcitations
- 2019Dipyridamole-loaded 3D-printed bioceramic scaffolds stimulate pediatric bone regeneration in vivo without disruption of craniofacial growth through facial maturitycitations
- 2019Regeneration of a Pediatric Alveolar Cleft Model Using Three-Dimensionally Printed Bioceramic Scaffolds and Osteogenic Agentscitations
- 2018Form and functional repair of long bone using 3D-printed bioactive scaffoldscitations
- 2018Dipyridamole enhances osteogenesis of three-dimensionally printed bioactive ceramic scaffolds in calvarial defectscitations
- 2018Three dimensionally printed bioactive ceramic scaffold osseoconduction across critical-sized mandibular defectscitations
- 2017Controlling calcium and phosphate ion release of 3D printed bioactive ceramic scaffoldscitations
- 2017Biocompatibility and degradation properties of WE43 Mg alloys with and without heat treatmentcitations
- 2017Abstract 47. Dipyridamole-Containing 3D-Printed Bioactive Ceramic Scaffolds for the Treatment of Calvarial Defects
- 2015Geometrical versus Random beta-TCP Scaffolds: Exploring the Effects on Schwann Cell Growth and Behaviorcitations
- 2014The physicochemical characterization and in vivo response of micro/nanoporous bioactive ceramic particulate bone graft materialscitations
- 2014The in vivo effect of P-15 coating on early osseointegrationcitations
- 2013MicroCT analysis of a retrieved root restored with a bonded fiber-reinforced composite dowelcitations
- 2012Physicochemical characterization and in vivo evaluation of amorphous and partially crystalline calcium phosphate coatings fabricated on Ti-6Al-4V implants by the plasma spray methodcitations
- 2012Abutment Design for Implant-Supported Indirect Composite Molar Crownscitations
- 2012Characterization and in vivo evaluation of laser sintered dental endosseous implants in dogscitations
- 2011Additive CAD/CAM process for dental prosthesescitations
Places of action
Organizations | Location | People |
---|
article
Hydrothermal aging affects the three-dimensional fit and fatigue lifetime of zirconia abutments
Abstract
<p>Objective: Evaluate the effect of aging using two different methods on the three-dimensional fit of zirconia abutments at the implant-abutment connection and estimate the probability of survival of anterior crowns supported by straight and 17-degree angled abutments. Materials and methods: Two different zirconia abutment designs, straight and 17-degree angled abutments (n = 63/group), were evaluated in the current study. The abutments were randomly allocated into three experimental groups according to laboratory aging condition (134°C, 2.2 bar, 20 h): (i) control, (ii) autoclave aging, and (iii) hydrothermal reactor aging. Crystalline content was determined by X-Ray diffraction (XRD) and Raman spectroscopy, and microstructure was analyzed using field-emission gun scanning electron microscope (FEG-SEM). Implant-abutment volume misfit was determined in the straight abutments by micro-computed tomography using the silicone replica technique. For fatigue testing, abutments were torqued to the implants and connected to standardized maxillary incisor zirconia crowns. The assemblies were subjected to step-stress accelerated life testing (SSALT) in water until fracture or suspension. The use level probability Weibull curves and probability of survival for a mission of 50,000 cycles at 50, 100, 150 and 200 N were calculated and plotted. Fractured samples were analyzed using a stereomicroscope and scanning electron microscope. Results: The crystalline spectra depicted a zirconia system primarily composed of the tetragonal phase. Laboratory aging yielded a 20%- and 37%-increase in the monoclinic content for abutments aged in autoclave and hydrothermal reactor relative to control, respectively. A fully crystalline matrix with a regular grain size was observed in the FEG-SEM for control abutments, with a considerable presence of intergranular defects. While autoclave aging triggered no significant alteration to the microstructure, defect population was reduced after hydrothermal reactor aging. Control abutments presented a significantly higher volume misfit (2.128 ± 0.54 mm<sup>3</sup>) relative to aged abutments using autoclave (1.244 ± 0.48 mm<sup>3</sup>) or hydrothermal reactor (1.441 ± 0.41 mm<sup>3</sup>). The beta (β) values indicated that failures were predominantly controlled by material strength rather than fatigue damage accumulation for all groups, except for straight control abutments. Irrespective of aging, the probability of survival of straight and angled zirconia abutments was up to 95% (95–100%) at 50 and 100 N. A 50N-increase in the load resulted in wider range of survival estimate, with straight autoclave abutments percentage significantly lower probability of survival (77%) than angled hydrothermal reactor abutments (99%). At 200N, angled hydrothermal reactor (97%) or autoclave (82%) aged abutments demonstrated the highest probability of survival, angled control (71%) and straight hydrothermal reactor (69%) abutments intermediate values, and straight autoclave (23%) and control (7%) abutments the lowest estimate. The failure mode predominantly involved abutment and/or abutment screw fracture for both straight and angled abutments. Conclusions: Hydrothermal aging significantly influenced volume misfit, as well as the probability of survival of zirconia abutments at higher loads for both angled and straight abutments.</p>