People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Jalkh, Ernesto B. Benalcázar
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (7/7 displayed)
- 2022Temporary materials used in prosthodonticscitations
- 2022Stability of fatigued and aged ZTA compared to 3Y-TZP and Al2O3 ceramic systemscitations
- 2022Probability of survival and failure mode of endodontically treated incisors without ferrule restored with CAD/CAM fiber-reinforced composite (FRC) post-cores.citations
- 2021Effect of supplemental acid-etching on the early stages of osseointegrationcitations
- 2021Hydrothermal aging affects the three-dimensional fit and fatigue lifetime of zirconia abutmentscitations
- 2021Performance of crowns cemented on a fiber-reinforced composite framework 5-unit implant-supported prostheses: in silico and fatigue analyses.citations
- 2020Hydrothermal degradation methods affect the properties and phase transformation depth of translucent zirconia.citations
Places of action
Organizations | Location | People |
---|
article
Effect of supplemental acid-etching on the early stages of osseointegration
Abstract
<p>Purpose: To evaluate the effect of two surface modifications on early osseointegration parameters of conical implants in a translational pre-clinical model. Materials and methods: Conical implants with progressive trapezoidal threads and healing chambers were evaluated consisting of two different surface conditions: 1) Implacil surface (IMP Sur), and 2) Implacil surface + Supplemental Acid-etching (IMP Sur + AE). Surface characterization comprised of the evaluation of roughness parameters (S<sub>a</sub>, S<sub>q</sub> and S<sub>dr</sub>), surface energy and contact angle. Subsequently, implants were installed in the ilium crest of nine female sheep (weighing ~65 kg). Torque out, histological and histomorphometric analyses were conducted after 3 and 6 weeks in-vivo. The percentage of bone to implant contact (%BIC) and bone area fraction occupancy within implant threads (%BAFO) were quantified, and the results were analyzed using a general linear mixed model analysis as function of surface treatment and time in-vivo. Results: Supplemental acid etching significantly increased S<sub>a</sub> and S<sub>q</sub> roughness parameters without compromising the surface energy or contact angle, and no significant differences with respect to S<sub>dr</sub>. Torque-out testing yielded significantly higher values for IMP Sur + AE in comparison to the IMP Sur at 3- (62.78 ± 15 and 33.49 ± 15 N.cm, respectively) and 6-weeks (60.74 ± 15 and 39.80 ± 15 N.cm, respectively). Histological analyses depicted similar osseointegration features for both surfaces, where an intramembranous-type healing pattern was observed. At histomorphometric analyses, IMP Sur + AE implants yielded higher values of BIC in comparison to IMP Sur at 3- (40.48 ± 38 and 27.98 ± 38%, respectively) and 6-weeks (45.86 ± 38 and 34.46 ± 38%, respectively). Both groups exhibited a significant increase in %BAFO from 3 (~35%) to 6 weeks (~44%), with no significant differences between surface treatments. Conclusion: Supplemental acid-etching and its interplay with implant thread design, positively influenced the BIC and torque-out resistance at early stages of osseointegration.</p>