People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Ignatiadis, Ioannis
Bureau de Recherches Géologiques et Minières
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (34/34 displayed)
- 2024Corrosion Inhibition of Carbon Steel Immersed in Standardized Reconstituted Geothermal Water and Individually Treated with Four New Biosourced Oxazoline Molecules
- 2024Optimization of experimental conditions of PFOA defluorination using DMSO/NaOH mixture
- 2024Over a year follow-up of parameters of a cemento-bentonitic filling material (CBFM) and of the corrosion potential of a carbon steel lining submerged by the CBFM, in an underground gallery cell
- 2024Long term monitoring of physical and chemical parameters of a cemento-bentonitic filling material (CBFM) and of corrosion potential ofa horizontal pipe made of carbon steel, submerged by the CBFM intoa sealed cell of underground gallery
- 2024Influence of microstructure and pore saturation in measuring corrosion rates of a carbon steel API 5L X65 in contact with cement grout in future nuclear waste disposal program
- 2024Laboratory-Scale Implementation of Standardized Reconstituted Geothermal Water for Electrochemical Investigations of Carbon Steel Corrosioncitations
- 2023Numerical Insights into the Ability of Indirect Galvanostatic Pulse in Wenner Configuration to Locate Corroding Areas in Macrocell Corrosion of Steel in Concrete
- 2023Corrosion and inhibition of carbon steel XC38 in a standardized reconstituted geothermal water (SRGW) at 100°C and 120 bars of pressure in the absence or presence of biosourced inhibitors
- 2023Corrosion control of ruthenium oxy-hydroxide coating for the development of robust pH sensors: observation and monitoring of the near field of a nuclear waste disposal site
- 2023Influence of polysulfide radicals on the mechanisms and intensity of corrosion of a carbon steel API 5L X65 in contact with cement grout in future nuclear waste disposal program ; Influence des radicaux de polysulfures sur les mécanismes et l'intensité de la corrosion d'un acier au carbone API 5L X65 en contact avec un coulis de ciment dans un futur programme de stockage de déchets nucléaires
- 2023Corrosion Current Density of API 5L X65 Carbon Steel in Contact with Natural Callovian-Oxfordian Clay Pore Water, Assessed by Various Electrochemical Methods over 180 Dayscitations
- 2023Corrosion Current Density of API 5L X65 Carbon Steel in Contact with Natural Callovian-Oxfordian Clay Pore Water, Assessed by Various Electrochemical Methods over 180 Dayscitations
- 2023Influence of polysulfide radicals on the mechanisms and intensity of corrosion of a carbon steel API 5L X65 in contact with cement grout in future nuclear waste disposal program
- 2022Comparative study of the effectiveness of organic petro-or biosourced surfactants in inhibiting carbon steel corrosion in a standardized reconstituted geothermal water (RGW)
- 2022Assessement of electrochemical behaviour and of corrosion current density of the carbon steel API 5L X65 in contact with cement grout in a nuclear waste disposal program
- 2022Corrosion current density evolution of the carbon steel API 5L X65 in contact with natural callovo-oxfordian water assessed by various electrochemical methods
- 2022Corrosion current density evolution of the carbon steel API 5L X65 in contact with natural callovo-oxfordian water assessed by various electrochemical methods
- 2022Assessement of electrochemical behaviour and of corrosion current density of the carbon steel API 5L X65 in contact with cement grout in a nuclear waste disposal program
- 2022Comparative study of the effectiveness of organic petro-or biosourced surfactants in inhibiting carbon steel corrosion in a standardized reconstituted geothermal water (RGW)
- 2022Comparative study of the effectiveness of organic petro-or biosourced surfactants in inhibiting carbon steel corrosion in a standardized reconstituted geothermal water (RGW)
- 2022Mechanism and kinetics of reductive dechlorination of hexachlorobutadiene and hexachloroethane by bimetallic Pd/Fe microparticles using an indirect and continuous monitoring of iron corrosion
- 2022CORROSION DENSITY OF THE CARBON STEEL API 5L X65 IN CONTACT WITH CALLOVO-OXFORDIAN CLAY PORE WATER ASSESSED BY USING VARIOUS ELECTROCHEMICAL METHODS
- 2022CORROSION DENSITY OF THE CARBON STEEL API 5L X65 IN CONTACT WITH CALLOVO-OXFORDIAN CLAY PORE WATER ASSESSED BY USING VARIOUS ELECTROCHEMICAL METHODS
- 2022Mechanisms and kinetics of carbon steel corrosion/scaling and inhibition in actual or reconstituted and treated geothermal waters
- 2021Permittivity and electrical resistivity measurements and estimations during the recovery of DNAPL in saturated porous media: 2D tank experimentscitations
- 2021Mechanisms and kinetics of carbon steel corrosion/scaling and inhibition in actual or reconstituted and treated geothermal waters
- 2018Exploration into the ionic exchanges in the Ni/Fe Lamellar Double Hydroxide by in-situ techniques under polarization
- 2017Intercomparison of Ta and Ti solid-electrodes for pH measurements under oxic and anoxic conditions in reconstituted waters of a future nuclear waste disposal
- 2013Improved monitoring of the reductive dechlorination of PCE in polluted soils by using geophysical and electrochemical measurements carried out in columns
- 2012Mechanistic and kinetic study of pyrite (FeS2)-hydrogen (H2) interaction at 25°C using electrochemical techniques
- 2012Mechanistic study of pyrite reduction by hydrogen in NaCl 0.1 M at 90°C using electrochemical techniques
- 2012H-terminated polycrystalline boron doped diamond electrode for geochemical sensing into underground components of nuclear repositories
- 2003Development of an enzymatic amperometric biosensor using cytochromes C3 for the fast quantification of chromate bio-availability in the environment.
- 2002Development of an enzymatic amperometric biosensor using cytochromes C3 for the fast quantification of chromate bio-availability in the environment.
Places of action
Organizations | Location | People |
---|
article
Permittivity and electrical resistivity measurements and estimations during the recovery of DNAPL in saturated porous media: 2D tank experiments
Abstract
Pumping experiments were performed in a 2D tank in order to estimate the recovery yield and rate of pure heavy chlorinated organic compounds (DNAPL; dense non-aqueous phase liquids). Several operating configurations were considered: permeability of the saturated zone, pumping flow rates, addition of surfactant (to reduce capillary effects), and thermal treatment (to reduce DNAPL viscosity). The experiments were monitored with permittivity (ε) and electrical resistivity (ρ) measurements. The experiments were also monitored with photography allowing, based on image interpretation, to accurately convert optical densities into water saturations (Sw) and to validate the geophysical data collected. Average Sw were determined in all detection areas from permittivities and electrical resistivities. These average Sw were used to calculate theoretical permittivities using the complex refractive index model (CRIM) and theoretical electrical resistivities using Archie's law. We found a good correlation between measured permittivities and the estimated permittivities with image. Conversely, the correlation was less accurate between measured and estimated electrical resistivities except for low electrical resistivities (i.e. high Sw). It is therefore not possible to accurately quantify water saturations using electrical resistivity monitoring alone. However, the accuracy is sufficient (especially for high values of Sw) to highlight differences between the three considered treatment technologies (i.e. without enhancement, with chemical and/or thermal enhancements). A combination of monitored electrical resistivity (which provides an integrated vision of the cone of depression) and monitored permittivity (which provides accurate but spatially limited information), and imaging allows a more accurate calibration of the relationship between resistivities and Sw and quantification of remediation rates and yields.