People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Landuyt, Kirsten L. Van
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (8/8 displayed)
- 2023Degradation products of resin-based materials detected in saliva in vivocitations
- 2022Bisphenol A release from short-term degraded resin-based dental materialscitations
- 2022Identification of chemicals leaching from dental resin-based materials after in vitro chemical and salivary degradationcitations
- 2021Long-term elution of bisphenol A from dental compositescitations
- 2021Assessing the estrogenic activity of chemicals present in resin based dental composites and in leachates of commercially available composites using the ERα-CALUX bioassaycitations
- 2021Bisphenol A as degradation product of monomers used in resin-based dental materialscitations
- 2018Qualitative analysis of dental material ingredients, composite resins and sealants using liquid chromatography coupled to quadrupole time of flight mass spectrometrycitations
- 2018A novel high sensitivity UPLC-MS/MS method for the evaluation of bisphenol A leaching from dental materialscitations
Places of action
Organizations | Location | People |
---|
article
Long-term elution of bisphenol A from dental composites
Abstract
<p>OBJECTIVES: BPA release from composites on the short term has been reported in several in-vitro and in-vivo studies. However, it remains unclear whether these materials also leach BPA on the long term. Even though composites may release various (BPA-based) methacrylate monomers up to one year, quantitative data about BPA have not been reported due to the lack of a sensitive method to accurately quantify low levels of BPA. In this context, the aim of the study was to quantify the one-year release of BPA with an optimized analytical method.</p><p>METHODS: Composite disks (n = 6, 6 mm diameter and 2 mm height) from four commercial materials (G-ӕnial Posterior, Venus, Ceram.x mono and Filtek Supreme XTE) were immersed in 1 mL of water or ethanol as extraction solvent and stored in the dark at 37 °C. The extraction solvent was renewed weekly for a period of 52 weeks. Samples were derivatized with pyridine-3-sulfonyl chloride before analysis with ultra-pressure liquid chromatography tandem mass spectrometry (UPLC-MS/MS).</p><p>RESULTS: Derivatizing BPA increased the sensitivity of the analytical method and allowed accurate quantification of very low levels of BPA (i.e. 0.78 pmol BPA). BPA eluted continuously in ethanol from all four tested composites over a period of one year. BPA elution was clearly higher when ethanol was used as extraction solution. In water, BPA eluted could be detected up to one year, but levels could not be accurately quantified anymore after several weeks.</p><p>SIGNIFICANCE: Composites can be considered as a potential long-term source of BPA, and thus should not be neglected when assessing the overall exposure to endocrine disrupting chemicals.</p>