People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Jager, N. De
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (9/9 displayed)
- 2020Effect of different materials and undercut on the removal force and stress distribution in circumferential clasps during direct retainer action in removable partial denturescitations
- 2020Fatigue performance of distinct CAD/CAM dental ceramicscitations
- 2020Young’s modulus and poisson ratio of composite materialscitations
- 2018Does luting strategy affect the fatigue behavior of bonded Y-TZP ceramic?citations
- 2017Adhesive cementation promotes higher fatigue resistance to zirconia crownscitations
- 2015Mechanical performance of implant-supported posterior crownscitations
- 2012The influence of pigments on the slow crack growth in dental zirconiacitations
- 2010The influence of rotating fatigue on the bond strength of zirconia-composite interfacescitations
- 2008Influence of retainer design on two-unit cantilever resin-bonded glass fiber reinforced composite fixed dental prostheses: An in vitro and finite element analysis study
Places of action
Organizations | Location | People |
---|
article
Effect of different materials and undercut on the removal force and stress distribution in circumferential clasps during direct retainer action in removable partial dentures
Abstract
<p>Objectives: This study aimed to evaluate the effect of different materials and undercut on the removal force and stress distribution in the supporting tooth and in the circumferential clasp used in removable partial prosthesis. Methods: Upper molars prepared for Akers circumferential clasp with retention and opposing arm were modeled, scanned, elaborated with CAD software and the geometries imported in FEA and analyzed. Six different materials were selected for the clasp (Polyamide, Polyoxymethylene, Polyetheretherketone - PEEK, Gold alloy, Titanium and CoCr) and 3 different undercuts (0.25, 0.50 and 0.75 mm), totaling 18 groups. Results: The clasps presented greater stress in their structure and potentially greater damage to the dental enamel when made with rigid materials and with more undercut; however, they presented greater ability to remain in position. Significance: Polyamide with a higher undercut is an esthetic alternative to rigid metallic clasps. It showed promising behavior because it strongly reduces the damage to the enamel, and even with an undercut of 0.75, the retention is lower than for CoCr with a 0.25 undercut, and this retention might still be sufficient. Polyoxymethylene and Polyetheretherketone (PEEK) are not suitable materials for the clasps, because the maximum stress occurring during removal with higher undercuts is higher than the material strength.</p>