People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Addison, Owen
King's College London
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (43/43 displayed)
- 2022Temperature-Dependence Corrosion Behavior of Ti6Al4V in the Presence of HClcitations
- 2022Surface Free Energy Dominates the Biological Interactions of Postprocessed Additively Manufactured Ti-6Al-4Vcitations
- 2021Surface finish of additively manufactured metalscitations
- 2020Post Processing of 3D Printed Metal Scaffolds: a Preliminary Study of Antimicrobial Efficiencycitations
- 2020Photo-polymerisation variables influence the structure and subsequent thermal response of dental resin matricescitations
- 2019The antimicrobial efficacy of hypoxia mimicking cobalt oxide doped phosphate-based glasses against clinically relevant Gram positive, Gram negative bacteria and a fungal straincitations
- 2019The antimicrobial efficacy of hypoxia mimicking cobalt oxide doped phosphate-based glasses against clinically relevant Gram positive, Gram negative bacteria and a fungal strain
- 2019Novel Minimal Access Bone Anchored Hearing Implant Surgery and a New Surface Modified Titanium Implant, the Birmingham Experiencecitations
- 2019The influence of partial replacement of Cu with Ga on the corrosion behavior of Ti40Zr10Cu36PD14 metallic glassescitations
- 2019Strength-limiting damage in lithium silicate glass-ceramics associated with CAD–CAMcitations
- 2019The influence of partial replacement of Cu with Ga on the corrosion behavior of Ti 40 Zr 10 Cu 36 PD 14 metallic glassescitations
- 2019The Antimicrobial Efficacy of Hypoxia Mimicking Cobalt Oxide Doped Phosphate-Based Glasses against Clinically Relevant Gram Positive, Gram Negative Bacteria and a Fungal Straincitations
- 2018Time-dependent Enhanced Corrosion of Ti6Al4V in the Presence of H2O2 and Albumincitations
- 2018Tailoring selective laser melting process for titanium drug-delivering implants with releasing micro-channelscitations
- 2018In situ synchrotron X-ray diffraction characterization of corrosion products of a Ti-based metallic glass for implant applicationscitations
- 2017The impact of resin-coating on sub-critical crack extension in a porcelain laminate veneer materialcitations
- 2017The impact of endodontic access on the biaxial flexure strength of dentine-bonded crown substrates – an in vitro studycitations
- 2016Adding functionality with additive manufacturing : fabrication of titanium-based antibiotic eluting implantscitations
- 2016Data acquisition variability using profilometry to produce accurate mean total volumetric wear and mean maximum wear depth measurements for the OHSU oral wear simulatorcitations
- 2015A synergistic effect of albumin and H2O2 accelerates corrosion of Ti6Al4Vcitations
- 2015A synergistic effect of albumin and H 2 O 2 accelerates corrosion of Ti6Al4Vcitations
- 2015Lipopolysaccharide inhibits or accelerates biomedical titanium corrosion depending on environmental aciditycitations
- 2014Biaxial flexure strength determination of endodontically accessed ceramic restorationscitations
- 2014Strength determination of brittle materials as curved monolithic structurescitations
- 2013Initial fracture resistance and curing temperature rise of ten contemporary resin-based composites with increasing radiant exposurecitations
- 2013Can a soda-lime glass be used to demonstrate how patterns of strength dependence are influenced by pre-cementation and resin-cementation variables?citations
- 2013Testing rate and cementation seating load effects on resin-strengthening of a dental porcelain analoguecitations
- 2012Improved bonding of zirconia substructures to resin using a "glaze-on" techniquecitations
- 2012Titanium phosphate glass microspheres for bone tissue engineering.citations
- 2012Improving the standard of the standard for glass ionomerscitations
- 2012The crushing truth about glass ionomer restorativescitations
- 2011Transient and residual stresses in a pressable glass-ceramic before and after resin-cement coating determined using profilometrycitations
- 2011Transient and residual stresses induced during the sintering of two dentin ceramicscitations
- 2010Seating load parameters impact on dental ceramic reinforcement conferred by cementation with resin-cementscitations
- 2009Oxygen inhibition and incremental layer bond strengths of resin compositescitations
- 2009Adhesive cementation and the strengthening of all-ceramic dental restorationscitations
- 2008Application of analytical stress solutions to bi-axially loaded dental ceramic-dental cement bilayerscitations
- 2008Adhesive luting of all-ceramic restorations - The impact of cementation variables and short-term water storage on the strength of a feldspathic dental ceramic
- 2007Resin strengthening of dental ceramics-The impact of surface texture and silanecitations
- 2007The impact of modifying alumina air abrasion parameters on the fracture strength of a porcelain laminate restorative materialcitations
- 2007The impact of hydrofluoric acid surface treatments on the performance of a porcelain laminate restorative materialcitations
- 2007Resin elasticity and the strengthening of all-ceramic restorationscitations
- 2004The influence of cement lute, thermocycling and surface preparation on the strength of a porcelain laminate veneering materialcitations
Places of action
Organizations | Location | People |
---|
article
Application of analytical stress solutions to bi-axially loaded dental ceramic-dental cement bilayers
Abstract
<p>Objective: Increased consideration of dental ceramics and dental cements as a singular structural unit for in-vitro mechanical testing has resulted in the reporting of a wide range of analytical methods to calculate the failure stresses. Therefore a comparison of observations between studies is complicated by the use of dissimilar stress solutions despite the employment of a similar testing methodology and specimen geometry. Materials and methods: Three analytical solutions to calculate failure stresses in bi-axially loaded dental ceramic-dental cement bilayers were appraised for a commonly utilized testing geometry (ball-on-ring). Clinically relevant datasets were generated from the bi-axial flexure testing of uncoated and dental cement coated aluminous core ceramic exposed to differing ceramic surface preparations. A Weibull statistical approach was utilized in order to provide insight into the impact of the analytical method on both the scale (σ<sub>0</sub>) and distribution (m) of the failure stress data. Results: Calculation of the bi-axial flexure stress utilizing Timoshenko's analysis resulted in an increase in σ<sub>0</sub> for the uncoated (6%) and dental cement coated (11-12%) aluminous core ceramic, when compared with the bilayered solutions reported by Rosenstiel and Hsueh. However, the shape of the failure distributions illustrated by the consistency of m and associated 95% confidence intervals was not influenced by the analytical stress solution employed. Significance: The choice of the analytical method chosen to calculate failure stresses in bi-axially loaded dental ceramic-dental cement bilayers will impact on the magnitude of the reported strength. Comparison between the failure stresses of uncoated and cement coated dental ceramics is more accurately represented by bilayer solutions, which account for the mismatch between the elastic constants of dissimilar materials. However, within the context of dental cement coated dental ceramics of clinically relevant dimensions, the choice of solution is unlikely to impact on the interpretation of the observations previously reported in the dental literature.</p>