People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Zhao, Xiao Ling
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (14/14 displayed)
- 2020Bond performance between FRP tubes and seawater sea sand concrete after exposure to seawater conditioncitations
- 2020The effect of elevated temperatures on the compressive section capacity of pultruded GFRP profilescitations
- 2019Effect of fibers configuration and thickness on tensile behavior of GFRP laminates subjected to elevated temperaturescitations
- 2019Bond-slip behaviour between FRP tubes and seawater sea sand concretecitations
- 2019Effect of fibers configuration and thickness on tensile behavior of GFRP laminates exposed to harsh environmentcitations
- 2019Durability of pultruded GFRP tubes under sea water sea sand concrete
- 2019Bond strength durability between FRP tubes and seawater sea sand concrete under sea water condition
- 2017Effect of elevated temperature on the mechanical properties of high-strain-rate-induced partially damaged concrete and CFSTscitations
- 2017Classification of major cohorts of Australian pressurised cast iron water mains for pipe renewalcitations
- 2017Size-dependency of concrete-filled steel tubes subject to impact loadingcitations
- 2016Fracture behaviour and microstructural evolution of structural mild steel under the multi-hazard loading of high-strain-rate load followed by elevated temperaturecitations
- 2015Mechanical properties of ultra-high strength (Grade 1200) steel tubes under cooling phase of a firecitations
- 2015Innovative corrugated hollow columns utilizing ultra high strength steel tubes
- 2015Size dependency and boundary effects on the mechanical properties of concrete filled steel tubes under impact load
Places of action
Organizations | Location | People |
---|
article
The effect of elevated temperatures on the compressive section capacity of pultruded GFRP profiles
Abstract
<p>The compressive performance of glass fiber reinforced polymer (GFRP) profiles subjected to elevated temperature was investigated through a large number of (3 0 0) tests. The effects of profile cross-sectional area, slenderness, and temperature on the behavior of the GFRP profiles at temperatures ranging from 25 to 400 °C were determined. It was observed that the compressive strength of the GFRP profiles has been decreased by half as the temperature exceeded 90 °C, i.e., close to the glass transition temperature of the matrix. The temperature and ratio of cross-sectional area to external perimeter were determined as two major parameters affecting section capacity.</p>