People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Blunn, Gw
University of Portsmouth
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (21/21 displayed)
- 2023Accelerated Degradation of Poly-ε-caprolactone Composite Scaffolds for Large Bone Defectscitations
- 2022Design and in vivo testing of novel single-stage tendon graft using polyurethane nanocomposite polymer for tendon reconstructioncitations
- 2018Novel adaptive finite element algorithms to predict bone ingrowth in additive manufactured porous implantscitations
- 2018Novel adaptive finite element algorithms to predict bone ingrowth in additive manufactured porous implants.
- 2017Clinical cold welding of the modular total hip arthroplasty prosthesiscitations
- 2017Intrinsic osteoinductivity of porous titanium scaffold for bone tissue engineeringcitations
- 2017Fretting corrosion behavior of nitinol spinal rods in conjunction with titanium pedicle screwscitations
- 2016Corrosion at the head-neck interface of current designs of modular femoral componentscitations
- 2016Metal concentrations in the blood and tissues after implantation of titanium growth guidance sliding instrumentationcitations
- 2016Nanohydroxyapatite effect on the degradation, osteoconduction and mechanical properties of polymeric bone tissue engineered scaffoldscitations
- 2015The effect of frictional torque and bending moment on corrosion at the taper interfacecitations
- 2015Lessons from retrievalscitations
- 2015Analysis of retrieved growth guidance sliding LSZ-4D devices for early onset scoliosis and investigation of the use of nitinol rods for this systemcitations
- 2015Silicate-substituted calcium phosphate with enhanced strut porosity stimulates osteogenic differentiation of human mesenchymal stem cellscitations
- 2014Low dose of propranolol does not affect rat osteotomy healing and callus strengthcitations
- 2013Enhanced wear and corrosion in modular tapers in total hip replacement is associated with the contact area and surface topographycitations
- 2011Enhancing the soft tissue seal around intraosseous transcutaneous amputation prostheses using silanized fibronectin titanium alloycitations
- 2008Composite ceramic bone graft substitute in the treatment of locally aggressive benign bone tumours.citations
- 2006Porous Ti-6Al-4V bone replacement materials produced by Selective Laser Sintering (SLS)
- 2004The effect of diamond like carbon and hydroxyapatite coatings on soft tissue reactions to external fixation screws under load
- 2000Fractographic examination of racing greyhound central (navicular) tarsal bone failure surfaces using scanning electron microscopy
Places of action
Organizations | Location | People |
---|
article
Design and in vivo testing of novel single-stage tendon graft using polyurethane nanocomposite polymer for tendon reconstruction
Abstract
Severe trauma, failure of prior surgical repair, delayed presentation and excessive scarring around the flexor tendon bed often necessitate a two-stage surgical reconstruction, where a silicone spacer is used in the first stage to recreate the fibro-osseous tunnel through which the tendon graft can glide in the second stage. This staged procedure involves great commitment on the part of both patient and surgeon, over the course of several months, involving a prolonged period of rehabilitation that can be quite disruptive to the patient's life and work. Reducing this from a two-stage into a single-stage procedure, therefore, has the potential to reduce rehabilitation time and cost, expedite return to work, and improve outcomes. To address this, we developed polyurethane (PU) nanocomposite, as an engineered tendon sheath, for treatment of delayed flexor tendon division as a single-stage procedure. The clinically conformant tubular grafts were tested for their efficacy in the peroneus tertius tendon of 6 Mule sheep for 3 months. Semi-quantitative histological assessment was carried out by analysing four descriptive layers: tendon, tendon/polymer sheath interface, polymer sheath, and polymer sheath/surrounding tissue. Four (out of 6) of the implanted PU nanocomposites showed moderate to substantial healing of the injured tendons, with minimal adhesion after repair, ensuring good gliding movement. No statistical differences were observed in tendon repair based on intra-regional variation in the explanted grafts, indicating homogeneity in tendon repair. Overall, the PU nanocomposite bears morphological stability and functionality for tendon repair, in single-stage surgical reconstruction, demonstrating promising evidence for clinical translation.