People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Marco, M. P.
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (4/4 displayed)
- 2009Immunoassay for folic acid detection in vitamin-fortified milk based on electrochemical magneto sensorscitations
- 2007Electrochemical magneto immunosensing of antibiotic residues in milkcitations
- 2007Electrochemical biosensing of pesticide residues based on affinity biocomposite platformscitations
- 2006Electrochemical magnetoimmunosensing strategy for the detection of pesticides residuescitations
Places of action
Organizations | Location | People |
---|
article
Electrochemical magneto immunosensing of antibiotic residues in milk
Abstract
A novel electrochemical immunosensing strategy for the detection of sulfonamide antibiotics in milk based on magnetic beads is presented. Among the different strategies for immobilizing the class-specific anti-sulfonamide antibody to the magnetic beads - such as those based on the use of Protein A or carboxylate modified magnetic beads -,the best strategy was found to be the covalent bonding on tosyl-activated magnetic beads. The immunological reaction for the detection of sulfonamide antibiotics performed on the magnetic bead is based on a direct competitive assay using a tracer with HRP peroxidase for the enzymatic labelling. After the immunochemical reactions, the modified magnetic beads can be easily captured by a magneto sensor made of graphite-epoxy composite (m-GEC), which is also used as the transducer for the electrochemical immunosensing. The electrochemical detection is thus achieved through a suitable substrate for the enzyme HRP and an electrochemical mediator. The electrochemical approach is also compared with a novel magneto-ELISA with optical detection. The performance of the electrochemical immunosensing strategy based on magnetic beads was successfully evaluated using spiked milk samples, and the detection limit was found to be 1.44 μg L-1 (5.92 nmol L-1) for raw full cream milk. This strategy offers great promise for rapid, simple, cost-effective and on-site analysis of biological, food and environmental samples. © 2006 Elsevier B.V. All rights reserved.