- 2022A capaciflector provides continuous and accurate respiratory rate monitoring for patients at rest and during exercisecitations
- 2019Myosteatosis is associated with poor physical fitness in patients undergoing hepatopancreatobiliary surgerycitations
- 2016[A6 Cardiopulmonary exercise testing for collaborative decision making prior to major hepatobiliary surgery] Proceedings of the American Society for Enhanced Recovery/Evidence Based Peri-Operative Medicine 2016 Annual Congress of Enhanced Recovery and Perioperative Medicinecitations
Places of action
Organizations | Location | People |
---|
article
A capaciflector provides continuous and accurate respiratory rate monitoring for patients at rest and during exercise
Abstract
<p>Respiratory rate (RR) is a marker of critical illness, but during hospital care, RR is often inaccurately measured. The capaciflector is a novel sensor that is small, inexpensive, and flexible, thus it has the potential to provide a single-use, real-time RR monitoring device. We evaluated the accuracy of continuous RR measurements by capaciflector hardware both at rest and during exercise. Continuous RR measurements were made with capaciflectors at four chest locations. In healthy subjects (n = 20), RR was compared with strain gauge chest belt recordings during timed breathing and two different body positions at rest. In patients undertaking routine cardiopulmonary exercise testing (CPET, n = 50), RR was compared with pneumotachometer recordings. Comparative RR measurement bias and limits of agreement were calculated and presented in Bland–Altman plots. The capaciflector was shown to provide continuous RR measurements with a bias less than 1 breath per minute (BPM) across four chest locations. Accuracy and continuity of monitoring were upheld even during vigorous CPET exercise, often with narrower limits of agreement than those reported for comparable technologies. We provide a unique clinical demonstration of the capaciflector as an accurate breathing monitor, which may have the potential to become a simple and affordable medical device. Clinical trial number: NCT03832205 https://clinicaltrials.gov/ct2/show/NCT03832205registered February 6th, 2019.</p>