People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Braun, Jürgen
Charité - Universitätsmedizin Berlin
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (26/26 displayed)
- 2022Mechanical behavior of the hippocampus and corpus callosum: An attempt to reconcile ex vivo with in vivo and micro with macro properties.citations
- 2020Diagnostic performance of tomoelastography of the liver and spleen for staging hepatic fibrosiscitations
- 2019Sensitivity of multifrequency magnetic resonance elastography and diffusion-weighted imaging to cellular and stromal integrity of liver tissue.citations
- 2019Surface resonance of thin films of the Heusler half-metal Co2MnSi probed by soft x-ray angular resolved photoemission spectroscopy
- 2018Signature of a highly spin polarized resonance state at $mathrm{Co_{2}MnSi(0 0 1)/Ag(0 0 1)}$ interfacescitations
- 2018Combining viscoelasticity, diffusivity and volume of the hippocampus for the diagnosis of Alzheimer's disease based on magnetic resonance imaging.citations
- 2018Signature of a highly spin polarized resonance state at Co2MnSi(001)/Ag(001) interfaces
- 2017Vectorial spin polarization detection in multichannel spin-resolved photoemission spectroscopy using an Ir(001) imaging spin filtercitations
- 2015Cerebral multifrequency MR elastography by remote excitation of intracranial shear wavescitations
- 2015Tabletop magnetic resonance elastography for the measurement of viscoelastic parameters of small tissue samples.citations
- 2014High-resolution mechanical imaging of the kidney.citations
- 2014In vivo multifrequency magnetic resonance elastography of the human intervertebral diskcitations
- 2014In vivo time-harmonic multifrequency elastography of the human liver.citations
- 2013Compression-sensitive magnetic resonance elastography.citations
- 2013Isovolumetric elasticity alteration in the human heart detected by in vivo time-harmonic elastography.citations
- 2012Fractal network dimension and viscoelastic powerlaw behavior: I. A modeling approach based on a coarse-graining procedure combined with shear oscillatory rheometry.citations
- 2012Monitoring the formation of interface-confined mixture by photoelectron spectroscopycitations
- 2010Viscoelasticity-based MR elastography of skeletal muscle.citations
- 2010Viscoelastic properties of liver measured by oscillatory rheometry and multifrequency magnetic resonance elastography.citations
- 2008Non-invasive measurement of brain viscoelasticity using magnetic resonance elastography.citations
- 2008Diffusive diffraction observed with volume-selective STEAM MRS in 100microm water-filled capillaries.
- 2007Three-dimensional analysis of shear wave propagation observed by in vivo magnetic resonance elastography of the brain.citations
- 2007Noninvasive assessment of the rheological behavior of human organs using multifrequency MR elastography: a study of brain and liver viscoelasticity.citations
- 2006Shear wave group velocity inversion in MR elastography of human skeletal muscle.citations
- 2003Electromagnetic actuator for generating variably oriented shear waves in MR elastography.citations
- 2002Analysis of wave patterns in MR elastography of skeletal muscle using coupled harmonic oscillator simulations.
Places of action
Organizations | Location | People |
---|
article
In vivo multifrequency magnetic resonance elastography of the human intervertebral disk
Abstract
PurposeTo test in vivo magnetic resonance elastography (MRE) of the human intervertebral disk (IVD).MethodsThe feasibility of MRE in IVD was demonstrated in ex vivo bovine disks. Sixteen asymptomatic volunteers underwent multifrequency MRE of the lumbar spine (IVD L3/4 and L4/5, n = 32) using a posterior plate transducer connected to a loudspeaker and operated at five frequencies from 50 to 70 Hz. Full wave field data were acquired in 10 transverse slices of 2 × 2 × 2 mm3 resolution. High-resolution maps of magnitude |G*| and phase angle φ of complex shear modulus G* were generated by multifrequency dual elasto visco (MDEV) inversion. Disk morphology was assessed by the Pfirrmann score (Pf).ResultsMorphological Pf was 1 in 25, 2 in 3, and 3 in 4 disks. |G*| decreased with Pf by a Pearson's linear correlation coefficient of R = −0.592 (P = 0.0004), while φ remained unchanged. Group mean mechanical parameters for Pf = 1 to 3 were |G*| = 6.51 ± 1.27, 5.29 ± 0.95, 4.03 ± 0.99 kPa, and φ = 1.190 ± 0.181, 1.170 ± 0.156, 1.088 ± 0.084 rad, respectively (p[Pf1-Pf3] < 0.001). The variability of mechanical parameters in one volunteer including diurnal changes was approximately 11%.ConclusionMultifrequency MRE with MDEV inversion allows measurement of in vivo mechanical properties of IVDs and may provide additional information in disc degeneration beyond standard morphological changes. Magn Reson Med 74:1380–1387, 2015. © 2014 Wiley Periodicals, Inc.