People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Sinkus, Ralph
King's College London
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (15/15 displayed)
- 2024Biomechanical Assessment of Liver Integrity: Prospective Evaluation of Mechanical Versus Acoustic <scp>MR</scp> Elastographycitations
- 2020On the origin of frequency power-law for tissue mechanics in elastography
- 2019Magnetic resonance elastography of skeletal muscle deep tissue injurycitations
- 2019Magnetic resonance elastography of skeletal muscle deep tissue injury
- 2015MR Elastography Can Be Used to Measure Brain Stiffness Changes as a Result of Altered Cranial Venous Drainage During Jugular Compressioncitations
- 2014Tumour biomechanical response to the vascular disrupting agent ZD6126 in vivo assessed by magnetic resonance elastography.citations
- 2014Viscoelastic parameters for quantifying liver fibrosiscitations
- 2013Measuring anisotropic muscle stiffness properties using elastographycitations
- 2013Curl-based Finite Element Reconstruction of the Shear Modulus Without Assuming Local Homogeneitycitations
- 2011Using static preload with magnetic resonance elastography to estimate large strain viscoelastic properties of bovine livercitations
- 2011Viscoelastic properties of the tongue and soft palate using MR elastographycitations
- 2009Magnetic resonance elastography in the liver at 3 Tesla using a second harmonic approachcitations
- 2008In vivo brain viscoelastic properties measured by magnetic resonance elastographycitations
- 2007MR elastography of breast lesionscitations
- 2005Imaging anisotropic and viscous properties of breast tissue by magnetic resonance-elastographycitations
Places of action
Organizations | Location | People |
---|
article
Magnetic resonance elastography in the liver at 3 Tesla using a second harmonic approach
Abstract
Magnetic resonance elastography (MRE) using mechanical stimulation has demonstrated diagnostic value and clinical promise in breast, liver, and kidney at 1.5 Tesla (T). However, MRE at 1.5T suffers from long imaging times and would benefit from greater signal-to-noise for more robust postprocessing. We present an MRE sequence modified for liver imaging at 3.0T. To avoid artifacts in the phase images, the sequence maintains a short TE by using a second harmonic approach, including stronger motion encoding gradients, shorter radio frequency pulses and an echo-planar readout. Scan time was decreased by a factor of approximately 2 relative to 1.5T by using an EPI readout and a higher density sampling of the phase waveform was used to calculate shear stiffness and viscosity. Localized (small region of interest) and global (whole-liver region of interest) measurements in normal healthy subjects compared very favorably with previously published results at 1.5T. There was no significant difference between global and localized measures.