People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Sharma, Prashant K.
University Medical Center Groningen
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (17/17 displayed)
- 2023Modulating the water behavior, microstructure, and viscoelasticity of plasma-derived hydrogels by adding silica nanoparticles with tailored chemical and colloidal propertiescitations
- 2022Viscoelastic properties of plasma-agarose hydrogels dictate favorable fibroblast responses for skin tissue engineering applicationscitations
- 2021Chemical and mechanical influence of root canal irrigation on biofilm removal from lateral morphological features of simulated root canals, dentine discs and dentinal tubulescitations
- 2019Chemical biofilm removal capacity of endodontic irrigants as a function of biofilm structurecitations
- 2019Chemical efficacy of several NaOCl concentrations on biofilms of different architecturecitations
- 2019Factors affecting the chemical efficacy of 2% sodium hypochlorite against oral steady-state dual-species biofilmscitations
- 2018Notochordal cell matrix as a bioactive lubricant for the osteoarthritic jointcitations
- 2017Implant Failurecitations
- 2013Stress relaxation analysis facilitates a quantitative approach towards antimicrobial penetration into biofilmscitations
- 2013A Distinguishable Role of eDNA in the Viscoelastic Relaxation of Biofilmscitations
- 2009Tunable Visible Emission of Ag-Doped CdZnS Alloy Quantum Dots
- 2009Bacterial Adhesion to Diamond-like Carbon as Compared to Stainless Steelcitations
- 2009Hyphal content determines the compression strength of Candida albicans biofilmscitations
- 2008Physicochemical and microbial fouling characterization of novel, extremely hydrophobic, nanocomposite diamond like carbon polymer hybrid coatings
- 2007Low-load compression testingcitations
- 2007Low-load compression testing:a novel way of measuring biofilm thicknesscitations
- 2001Surface chemical characterisation of Paenibacillus polymyxa before and after adaptation to sulfide mineralscitations
Places of action
Organizations | Location | People |
---|
article
Bacterial Adhesion to Diamond-like Carbon as Compared to Stainless Steel
Abstract
Recent studies suggest that diamond-like carbon (DLC) coatings are suitable candidates for application on biomedical devices and implants, due to their high hardness, low friction, high wear and corrosion resistance, chemical inertness, smoothness, and tissue and blood compatibility. However, most studies have neglected the potential susceptibility of DLC coatings to bacterial adhesion, which is the first step in the development of implant-related infections. This study compares adhesion of seven bacterial strains, commonly implicated in implant-related infections, to tetrahedral amorphous carbon, with their adhesion to AISI 316L surgical steel. The results show that bacterial adhesion to DLC was similar to the adhesion to commonly used stainless steel. This suggests that DLC coating can be advantageously used on implants made of AISI 316L or other materials without increasing the risk to implant-related infections. (C) 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 90B: 882-885, 2009