Topics
Publications (6/6 displayed)
- 2020Soft sensors for a sensing-actuation system with high bladder voiding efficiencycitations
- 2018Integration of a Quantum Tunneling Composite-Based Sensor with the Flexible Actuator for Neurogenic Underactive Bladder
- 2018Toward Self-Control Systems for Neurogenic Underactive Bladdercitations
- 2018Design and Anchorage Dependence of Shape Memory Alloy Actuators on Enhanced Voiding of a Bladdercitations
- 2017A 3D Printed Implantable Device for Voiding the Bladder Using Shape Memory Alloy (SMA) Actuatorscitations
- 2017A 3D Printed Implantable Device for Voiding the Bladder Using Shape Memory Alloy (SMA) Actuatorscitations
Places of action
Organizations | Location | People |
---|
article
A 3D Printed Implantable Device for Voiding the Bladder Using Shape Memory Alloy (SMA) Actuators
Abstract
<p>Underactive bladder or detrusor underactivity (DU) is defined as a reduction of contraction strength or duration of the bladder wall. Despite the serious healthcare implications of DU, there are limited solutions for affected individuals. A flexible 3D printed implantable device driven by shape memory alloys (SMA) actuators is presented here for the first time to physically contract the bladder to restore voluntary control of the bladder for individuals suffering from DU. This approach is used initially in benchtop experiments with a rubber balloon acting as a model for the rat bladder to verify its potential for voiding, and that the operating temperatures are safe for the eventual implantation of the device in a rat. The device is then implanted and tested on an anesthetized rat, and a voiding volume of more than 8% is successfully achieved for the SMA-based device without any surgical intervention or drug injection to relax the external sphincter.</p>