People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Poźniak, Krzysztof
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (18/18 displayed)
- 2019Multichannel Data Acquisition System for GEM Detectors citations
- 2018Advanced real-time data quality monitoring model for tokamak plasma diagnosticscitations
- 2017FPGA-based firmware model for extended measurement systems with data quality monitoring citations
- 2016 Modeling of serial data acquisition structure for GEM detector system in Matlabcitations
- 2016New trends in logic synthesis for both digital designing and data processing citations
- 2016The development of algorithms for the deployment of new version of GEM-detector-based acquisition systemcitations
- 2015Architecture of the Upgraded BCM1F backend Electronics for Beam Conditions and Luminosity Measurementcitations
- 2015The CMS Fast Beams Condition Monitor Back-End Electronics based on MicroTCA technology – status and development
- 2015FPGA based charge acquisition algorithm for soft X-ray diagnostics systemcitations
- 2015Development of low noise CCD readout front-end citations
- 2015OMTF firmware overviewcitations
- 2014Development of GEM Gas Detectors for X-Ray Crystal Spectrometry citations
- 2014The Fast Beam Condition Monitor BCM1F Backend Electronics Upgraded MicroTCA Based Architecturecitations
- 2013Fundamental Data Processing for GEM Detector Measurement System Applied for X - ray Diagnostics of Fusion Plasmas
- 2011Optimization of FPGA processing of GEM detector signal citations
- 2011Development of a 1D Triple GEM X-ray detector for a high-resolution x-ray diagnostics at JET
- 2005Optical network and FPGA/DSP based control system for free electon laser
- 2003Cavity Digital Control Testing System by Simulink Step Operation Method for TESLA Linear Accelerator and Free Electron Laser
Places of action
Organizations | Location | People |
---|
report
Cavity Digital Control Testing System by Simulink Step Operation Method for TESLA Linear Accelerator and Free Electron Laser
Abstract
The cavity control system for the TESLA-TeV–Energy Superconducting LinearAccelerator project is initiallyintroduced in this paper. The FPGA – Field Programmable Gate Array technology has been implemented for digitalcontroller stabilizing cavity field gradient. The cavity SIMULINK model has been applied to test the hardwarecontroller. The step operation method has been developed for testing the FPGA device coupled to the SIMULINKmodel of the analog real plant. The FPGA signal processing has been verified according to the required algorithm of thereference MATLAB controller. Some experimental resultshave been presented for different cavity operationalconditions.