People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Klein, Marcus
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (11/11 displayed)
- 2024On the Monotonic and Cyclic Behavior of an Al‐Mg‐Zn‐Cu‐Si Compositionally Complex Alloy
- 2023On the Monotonic and Cyclic Behavior of an Al‐Mg‐Zn‐Cu‐Si Compositionally Complex Alloycitations
- 2023Increase in residual lifetime due to low amplitude cycles and dwell times at room temperature: Observations and suspected mechanisms
- 2022Robust determination of fatigue crack propagation thresholds from crack growth datacitations
- 2021On the Influence of Control Type and Strain Rate on the Lifetime of 50CrMo4
- 2020On the Influence of Control Type and Strain Rate on the Lifetime of 50CrMo4citations
- 2018Determination of the anisotropic fatigue behaviour of additively manufactured structures with short-time procedure PhyBaL<sub>LIT</sub>citations
- 2016Automated detection of yarn orientation in 3D-draped carbon fiber fabrics and preforms from eddy current datacitations
- 2014Defect detection in carbon fiber non-crimp fabrics and CRFP with high-frequency eddy current technique ; Fehlererkennung an glatten Kohlenstofffasergeweben und CFRP mittels Hochfrequenzwirbelstrom-Technik
- 2008Full Scale Test of a SSP 34m boxgirder 2:Data report
- 2008Full Scale Test of a SSP 34m boxgirder 2
Places of action
Organizations | Location | People |
---|
report
Full Scale Test of a SSP 34m boxgirder 2
Abstract
This report presents the setup and result from three static full-scale tests of the reinforced glass fiber/epoxy box girder used in a 34m wind turbine blade. One test was without reinforcement one with cap reinforcement and the final test was with rib reinforcement. The cap reinforcement test was part of a proof of concept investigation for a patent. The tests were performed at the Blaest test facility in August 2007. The tests are an important part of a research project established in cooperation between Risø National Laboratory for sustainable energy – Technical university of Denmark, SSP-Technology A/S and Blaest (Blade test centre A/S) and it has been performed as a part of Find Mølholt Jensen’s PhD thesis. This report is the second data report containing the complete test data for the three full-scale tests. This report deals only with the test methods and the obtained results, no conclusions are drawn. These can be found in papers and patent referenced in the data report. Various kinds of measuring equipment have been used during these tests: acoustic emission, force transducers, strain gauges and optical deformation measuring system (DIC). The experimental investigation consisted of the following tests: 1) Flapwise bending with no reinforcement 2) Flapwise bending with wire reinforcements 3) Flapwise bending with rib reinforcements