People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Shaheen, Eman
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (1/1 displayed)
Places of action
Organizations | Location | People |
---|
article
Trueness of cone-beam computed tomography-derived skull models fabricated by different technology-based three-dimensional printers
Abstract
<jats:title>Abstract</jats:title><jats:sec><jats:title>Background</jats:title><jats:p>Three-dimensional (3D) printing is a novel innovation in the field of craniomaxillofacial surgery, however, a lack of evidence exists related to the comparison of the trueness of skull models fabricated using different technology-based printers belonging to different cost segments. </jats:p></jats:sec><jats:sec><jats:title>Methods</jats:title><jats:p>A study was performed to investigate the trueness of cone-beam computed tomography-derived skull models fabricated using different technology based on low-, medium-, and high-cost 3D printers. Following the segmentation of a patient’s skull, the model was printed by: (i) a low-cost fused filament fabrication printer; (ii) a medium-cost stereolithography printer; and (iii) a high-cost material jetting printer. The fabricated models were later scanned by industrial computed tomography and superimposed onto the original reference virtual model by applying surface-based registration. A part comparison color-coded analysis was conducted for assessing the difference between the reference and scanned models. A one-way analysis of variance (ANOVA) with Bonferroni correction was applied for statistical analysis.</jats:p></jats:sec><jats:sec><jats:title>Results</jats:title><jats:p>The model printed with the low-cost fused filament fabrication printer showed the highest mean absolute error (<jats:inline-formula><jats:alternatives><jats:tex-math>1.33 0.24 {mm}</jats:tex-math><mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>1.33</mml:mn><mml:mo>±</mml:mo><mml:mn>0.24</mml:mn><mml:mtext>mm</mml:mtext></mml:mrow></mml:math></jats:alternatives></jats:inline-formula>), whereas both medium-cost stereolithography-based and the high-cost material jetting models had an overall similar dimensional error of <jats:inline-formula><jats:alternatives><jats:tex-math>0.07 0.03 {mm}</jats:tex-math><mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>0.07</mml:mn><mml:mo>±</mml:mo><mml:mn>0.03</mml:mn><mml:mtext>mm</mml:mtext></mml:mrow></mml:math></jats:alternatives></jats:inline-formula> and <jats:inline-formula><jats:alternatives><jats:tex-math>0.07 0.01 {mm}</jats:tex-math><mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>0.07</mml:mn><mml:mo>±</mml:mo><mml:mn>0.01</mml:mn><mml:mtext>mm</mml:mtext></mml:mrow></mml:math></jats:alternatives></jats:inline-formula>, respectively. Overall, the models printed with medium- and high-cost printers showed a significantly (<jats:inline-formula><jats:alternatives><jats:tex-math>p<0.01</jats:tex-math><mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mi>p</mml:mi><mml:mo><</mml:mo><mml:mn>0.01</mml:mn></mml:mrow></mml:math></jats:alternatives></jats:inline-formula>) lower error compared to the low-cost printer.</jats:p></jats:sec><jats:sec><jats:title>Conclusions</jats:title><jats:p>Both stereolithography and material jetting based printers, belonging to the medium- and high-cost market segment, were able to replicate the skeletal anatomy with optimal trueness, which might be suitable for patient-specific treatment planning tasks in craniomaxillofacial surgery. In contrast, the low-cost fused filament fabrication printer could serve as a cost-effective alternative for anatomical education, and/or patient communication.</jats:p></jats:sec>