People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Thomson, David
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (8/8 displayed)
- 2022Effect of dentine site on resin and cement adaptation tested using X-ray and electron microscopy to evaluate bond durability and adhesive interfacescitations
- 2020Silicon erasable waveguides and directional couplers by germanium ion implantation for configurable photonic circuitscitations
- 2018Real-time monitoring and gradient feedback enable accurate trimming of ion-implanted silicon photonic devicescitations
- 2017Phase trimming of Mach-Zehnder Interferometers by laser annealing of germanium implanted waveguidescitations
- 2017Post-fabrication phase trimming of Mach-Zehnder Interferometers by laser annealing of germanium implanted waveguidescitations
- 2017Trimming of ring resonators via ion implantation in siliconcitations
- 2016Electron channelling contrast imaging for III-nitride thin film structurescitations
- 2008Use of sonication and influence of clay type on the enhancement in physical properties of poly(methyl methacrylate) nanocomposites
Places of action
Organizations | Location | People |
---|
article
Effect of dentine site on resin and cement adaptation tested using X-ray and electron microscopy to evaluate bond durability and adhesive interfaces
Abstract
Glass ionomer (GI) cements and self-etch (SE) or universal adhesives after etching (ER) adapt variably with dentine. Dentine characteristics vary with depth (deep/shallow), location (central/peripheral), and microscopic site (intertubular/peritubular). To directly compare adhesion to dentine, non-destructive imaging and testing are required. Here, GI, ER, and SE adapted at different dentine depths, locations, and sites were investigated using micro-CT, xenon plasma focused ion beam scanning electron microscopy (Xe PFIB-SEM), and energy dispersive X-ray spectroscopy (EDS). Extracted molars were prepared to deep or shallow slices and treated with the three adhesives. Micro-CT was used to compare changes to air volume gaps, following thermocycling, and statistically analysed using a quantile regression model and Fisher's exact test. The three adhesives performed similarly across dentine depths and locations, yet no change or overall increases and decreases in gaps at all dentine depths and locations were measured. The Xe PFIB-SEM-milled dentine-adhesive interfaces facilitated high-resolution characterization, and element profiling revealed variations across the tooth-material interfaces. Dentine depth and location had no impact on adhesive durability, although microscopic differences were observed. Here we demonstrate how micro-CT and Xe PFIB-SEM can be used to compare variable dental materials without complex multi-stage specimen preparation to minimize artefacts.