People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Czarski, Tomasz
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (10/10 displayed)
- 2019Multichannel Data Acquisition System for GEM Detectors citations
- 2016 Modeling of serial data acquisition structure for GEM detector system in Matlabcitations
- 2016The development of algorithms for the deployment of new version of GEM-detector-based acquisition systemcitations
- 2015FPGA based charge acquisition algorithm for soft X-ray diagnostics systemcitations
- 2014Development of GEM Gas Detectors for X-Ray Crystal Spectrometry citations
- 2013Fundamental Data Processing for GEM Detector Measurement System Applied for X - ray Diagnostics of Fusion Plasmas
- 2011Optimization of FPGA processing of GEM detector signal citations
- 2011Development of a 1D Triple GEM X-ray detector for a high-resolution x-ray diagnostics at JET
- 2005Optical network and FPGA/DSP based control system for free electon laser
- 2003Cavity Digital Control Testing System by Simulink Step Operation Method for TESLA Linear Accelerator and Free Electron Laser
Places of action
Organizations | Location | People |
---|
article
Development of GEM Gas Detectors for X-Ray Crystal Spectrometry
Abstract
Two Triple Gas Electron Multiplier (Triple-GEM) detectors were developed for high-resolution X-ray spectroscopy measurements for tokamak plasma to serve as plasma evolution monitoring in soft X-ray region (SXR). They provide energy resolved fast dynamic plasma radiation imaging in the SXR with 0.1 kHz frequency. Detectors were designed and constructed for continuous data-flow precise energy and position measurement of plasma radiation emitted by metal impurities, W46+ and Ni26+ ions, at 2.4 keV and 7.8 keV photon energies, respectively. High counting rate capability of the detecting units has been achieved with good position resolution. This article presents results of the laboratory and tokamak experiments together with the system performance under irradiation by photon flux from the plasma core.