People | Locations | Statistics |
---|---|---|
Naji, M. |
| |
Motta, Antonella |
| |
Aletan, Dirar |
| |
Mohamed, Tarek |
| |
Ertürk, Emre |
| |
Taccardi, Nicola |
| |
Kononenko, Denys |
| |
Petrov, R. H. | Madrid |
|
Alshaaer, Mazen | Brussels |
|
Bih, L. |
| |
Casati, R. |
| |
Muller, Hermance |
| |
Kočí, Jan | Prague |
|
Šuljagić, Marija |
| |
Kalteremidou, Kalliopi-Artemi | Brussels |
|
Azam, Siraj |
| |
Ospanova, Alyiya |
| |
Blanpain, Bart |
| |
Ali, M. A. |
| |
Popa, V. |
| |
Rančić, M. |
| |
Ollier, Nadège |
| |
Azevedo, Nuno Monteiro |
| |
Landes, Michael |
| |
Rignanese, Gian-Marco |
|
Schladitz, Frank
in Cooperation with on an Cooperation-Score of 37%
Topics
Publications (6/6 displayed)
- 2020Electrical Material Properties of Carbon Reinforced Concretecitations
- 2019Dielectric Material Characterization for 5G Propagation Modellingcitations
- 2019Carbon reinforced concrete and temperature
- 2019Untersuchung von Betonproben mit CFK- und GFK-Bewehrung mittels Röntgen-Computertomografie und -laminografiecitations
- 2018Parking slabs made of carbon reinforced concretecitations
- 2018Future applications in carbon reinforced concrete (CRC)
Places of action
Organizations | Location | People |
---|
article
Untersuchung von Betonproben mit CFK- und GFK-Bewehrung mittels Röntgen-Computertomografie und -laminografie
Abstract
Examination of concrete samples with CFRP and GFRP reinforcement by X-ray computed tomography and laminography – concrete samples with CFRP and GFRP reinforcement. Non-metallic reinforcements are already widely used in concrete construction today. Up to now, material testing has mainly been carried out under destructive conditions. As a consequence, the position of the reinforcement within the concrete matrix is determined by inspection and measurement of saw cut interfaces. Imaging procedures as X-ray computed tomography (XCT) and laminography (XCL) enable the nondestructive evaluation and location of carbon and glass fiber reinforcements within the volume of a concrete structure platform. The concrete cover as well as the yarn cross-section, spacing and the position of the reinforcement can be determined in the concrete matrix by XCT, the latter with a deviation of < 0.2 mm in comparison with the destructive control measurements of the previous method by means of a measuring microscope. A special combination of limited-angle X-ray computed tomography (LAT) followed by XCL has been shown to increase the detailed recognition of the reconstructed sectional images compared to the individual procedures.